LIDAR RESEARCHER:
Dr. Thomas Trickl
RESEARCH ASSOCIATES: Hannes Vogelmann
MAILING ADDRESS: Kreuzeckbahnstr. 19, D-82467
Garmisch-Partenkirchen, Germany
TELEPHONE NUMBER: (+49)-8821-183-209
FAX NUMBER: (+49)-8821-73573
E-MAIL ADDRESS: trickl@ifu.fhg.de
WEB SITE: http://www.ifu.fhg.de
DATE: August 14, 2001
LIDAR LOCATION (CITY, COUNTRY, LAT., LONG.): Garmisch-Partenkirchen,
Germany, 47.5 N, 11.0 E
SITE ELEVATION: 2700 m a.s.l. (Schneefernerhaus
on Mt. Zugspitze)
PARAMETER(S) OR CONSTITUENT(S) MEASURED: Tropospheric
water vapour
RESEARCH OBJECTIVES AND SPONSOR: Investigation
of water vapour in the free troposphere; sponsors: Bayerisches
Wirtschaftsministerium, German Bundesministerium für Bildung,
Forschung und Technologie
MEASUREMENT TECHNIQUE: Two-wavelength DIAL
MEASUREMENT RANGE: 3.0 to 13 km a.s.l.
VERTICAL RESOLUTION: dynamically set, 0.05 to
0.5 km
FREQ. OF MEASUREMENT (TYPICALLY): 1 measurement
per hour during selected episodes
MEASUREMENT TIMES (TYPICALLY): 10 min
LASER TYPE AND WAVELENGTH (s): Oscillator: 2 Single-longitudinal-mode
OPOs, sequentially amplified in a flashlamp-pumped 0.9-J Ti:Al2O3
amplifier; wavelengths will be chosen in the 810- or 940-nm bands
of H2O.
LASER ENERGY/PULSE: 0.8 J (800 nm)
PULSE REPETITION RATE: 20 Hz
RECEIVER SIZE AND CONFIGURATION: 650 mm Newtonian
telescope
DETECTORS USED: 3 APDs (Licel)
SIGNAL PROCESSING: 4 channels with 3 12 bit/20
MHz transient digitizers
ANALOG-T0-DIGITAL CONVERTER: 12 bit/20 MHz (Licel)
COMPUTER: PC
PLATFORM (if applicable): truck
PUBLICATIONS none
COMMENTS: System under development, is expected
to be finished in winter 2002
|